===heated roofs automation=== | ===heated roofs automation=== | ||
The first question that came to mind for this project was to be sure that there was a UL approved product that we could connect the control microcontroller to. There are a number of options. This one is the most flexible. It allows you override the automatic system and turn the heaters off and on from the relay | The first question that came to mind for this project was to be sure that there was a UL approved product that we could connect the control microcontroller to. There are a number of options. This one is the most flexible. It has a HOA switch (Hand control on, Off , or Automatic) that allows you override the automatic system and turn the heaters off and on from the relay if the internet or wifi go off. | ||
Right now the electrician is providing some kind of 220v DPDT switch. In the new scheme you would deliver the product with this [http://www.veris.com/Item/V431.aspx relay/switch] that mounts to the panel. In addition you would need to have them install a [http://www.homedepot.com/p/Packard-20VA-120-20-240-Volt-24-Volt-Secondary-2-ft-Mount-Transformer-PF42420/203565056?MERCH=REC-_-PIPHorizontal1_rr-_-202312933-_-203565056-_-N 24volt transformer] (like is used to control doorbells or zone valves) and an outlet for the microcontroller usb cord. | |||
Right now the electrician is providing | |||
====Veris V321 : Enclosed Power Duty Relay, 20A DPDT N.O., Coil: 24VAC/DC, 120VAC, w/2 HOA Switch, Relay Power LED, UL ==== | ====Veris V321 : Enclosed Power Duty Relay, 20A DPDT N.O., Coil: 24VAC/DC, 120VAC, w/2 HOA Switch, Relay Power LED, UL ==== |
Revision as of 15:45, 10 October 2015
heated roofs automation
The first question that came to mind for this project was to be sure that there was a UL approved product that we could connect the control microcontroller to. There are a number of options. This one is the most flexible. It has a HOA switch (Hand control on, Off , or Automatic) that allows you override the automatic system and turn the heaters off and on from the relay if the internet or wifi go off.
Right now the electrician is providing some kind of 220v DPDT switch. In the new scheme you would deliver the product with this relay/switch that mounts to the panel. In addition you would need to have them install a 24volt transformer (like is used to control doorbells or zone valves) and an outlet for the microcontroller usb cord.
Veris V321 : Enclosed Power Duty Relay, 20A DPDT N.O., Coil: 24VAC/DC, 120VAC, w/2 HOA Switch, Relay Power LED, UL
The Victory 321 DPST power duty enclosed relays combine an industrial-strength relay with installation flexibility...use the nipple mount to attach to any enclosure. One coil input controls the state of two power-rated contacts for simultaneous control of two devices, or both poles of a single-phase load. Each output is enabled with a Hand-Off-Auto switch for local control. The Victory series does not require a dedicated field enclosure, so it is ideal for retrofit projects. Field-selectable high and low voltage coil inputs provide on-site versatility.